Precision Barrier Testing for Tomorrow's Packaging
World-leading WVTR & OTR permeation analyzers trusted by global packaging, pharmaceutical, and food & beverage companies.
Industry Leaders Trust Our Precision
From Fortune 500 companies to innovative startups, powering quality control globally












Advanced Permeation Analysis Systems
Industry-leading barrier testing equipment for films, packages, and containers
Systech AquaSense 7101
High-precision WVTR analyzer with P₂O₅ coulometric sensor. No calibration required, absolute measurements from 0.002-1000 g/m²/day.
Systech OxySense 8101e
Advanced OTR analyzer with eMetric™ coulometric sensor (0.05-432,000 cc/m²/day). Features Auto-Stop™ and ±0.1°C temperature control.
Systech OxySense 8700/8701
Multi-sample package testing system. Test up to 11 samples simultaneously with results in 3+ hours. Ideal for bottles, pouches, and containers.
Systech OxySense 8102e (No RH)
Ultra-sensitive OTR analyzer without humidity control. Enhanced eMetric™ sensor (0.005-432,000 cc/m²/day) for high-barrier materials.
Lyssy L80-6000
Swiss-engineered WVTR analyzer with infrared sensor technology (0.01-6000 g/m²/day). ISO 15106 compliant with fast testing cycles.
Systech AquaSense 7101
High-Precision WVTR Testing with Coulometric Technology
Key Features
Systech OxySense 8101e
High-Performance OTR Testing with eMetric™ Technology
Key Features
Systech OxySense 8700/8701
Multi-Sample Package Permeation Testing Excellence
Key Features
Systech OxySense 8102e (No RH)
Ultra-Sensitive OTR Testing for Dry Conditions
Key Features
Lyssy L80-6000
Swiss Precision WVTR Testing with Infrared Technology
Key Features
Performance Metrics
Industry-leading specifications that set the standard
Absolute Measurement Technology
P₂O₅ coulometric sensors provide absolute measurements without calibration gas, eliminating drift issues common in carrier gas methods.
High-Throughput Testing
Test up to 11 samples simultaneously with individual start/stop control. Ultra-fast results enable rapid QC decisions and production adjustments.
Unmatched Dynamic Range
From ultra-high barrier pharmaceutical films to permeable food packaging—one system covers your entire testing spectrum.
Global Certification Ready
Meet all international standards for pharmaceutical, food, and packaging testing with built-in compliance documentation.
Key Advantages
What sets our barrier testing solutions apart
Coulometric Precision
P₂O₅ and eMetric™ sensors deliver absolute measurements without calibration—highest accuracy in the industry.
- No calibration required
- ±0.5% accuracy across range
- Long-term stability
Global Compliance
Every analyzer meets international testing standards—results recognized and accepted worldwide.
- ASTM D3985, F1249, F3299-18
- ISO 15105-2 & DIN certified
- Third-party validated
FITCO India Support
Comprehensive local support—spare parts, service, warranty, all handled by your authorized partner.
- Genuine spare parts
- Expert installation & training
- Warranty & service contracts
See Our Technology in Action
Watch our WVTR and OTR permeation analyzers deliver precision barrier testing results
4:25
OTR Permeation Testing
Oxygen transmission rate analysis for barrier packaging
5:12
WVTR Moisture Testing
Water vapor transmission rate for packaging films
6:38
Systech Illinois 8101e
OTR analyzer demonstration and capabilities
5:45
Systech Illinois 7101
WVTR analyzer for moisture barrier testing
4:52
Permeation Analysis
Complete gas permeation testing methodology
5:30
Barrier Testing
Packaging barrier testing for moisture protection
Critical Applications
Where Industrial Physics barrier testing makes the difference
Modified Atmosphere Packaging (MAP)
Ensure shelf-life extension for fresh produce and ready meals. OTR testing validates package integrity for MAP applications, where oxygen levels below 0.5% are critical for maintaining freshness and preventing spoilage.
Blister Pack & Bottle Testing
Validate moisture barrier properties for pharmaceutical stability. WVTR testing ensures drug efficacy by confirming package meets ICH stability guidelines. Critical for hygroscopic formulations requiring <0.01 g/m²/day protection.
High-Barrier Film Development
Characterize multilayer film structures for snack foods, coffee, and pet food applications. Measure ultra-low OTR values down to 0.0005 cc/m²/day for metallized and SiOx-coated films used in premium packaging.
In barrier testing, precision isn't a luxury—it's a mandate. We've reduced stability failures from 8% to near-zero by implementing proper WVTR testing protocols. Coulometric technology eliminates the calibration drift that plagued older sensors. When you're protecting ₹50 crore worth of active pharmaceutical ingredients, the ₹1.5 crore investment in proper permeation testing isn't optional—it's insurance that pays for itself within 18 months.
Did You Know?
Critical testing facts that impact your packaging quality
A pharmaceutical blister pack with WVTR above 0.02 g/m²/day can cause moisture-sensitive drugs to lose 15-30% potency within 6 months, leading to batch recalls costing ₹5-10 crores.
Moisture = Money Lost
AquaSense 7101 detects WVTR down to 0.002 g/m²/day
Coffee loses 50% of its aroma compounds within 2 weeks if packaged in film with OTR above 0.1 cc/m²/day. Premium brands require barrier films below 0.01 cc/m²/day for 12-month shelf life.
Freshness is Measurable
OxySense 8101e: Industry-leading 0.05 cc/m²/day sensitivity
Coulometric sensors provide ABSOLUTE measurements—no calibration gas required. This eliminates the 2-5% drift seen in carrier gas methods, saving ₹3-5 lakhs annually in calibration costs and preventing false readings.
Calibration-Free Accuracy
P₂O₅ & eMetric™ technology sets the global standard
Achieve Unmatched Barrier Testing Accuracy—Starting Today
Join 500+ global brands reducing packaging defects by 45% with ASTM-compliant WVTR & OTR analyzers. Get expert support from India's #1 testing equipment distributor.