8101e OxySense® Oxygen Transmission Rate Analyzer (OTR)

Brought to you by Systech Illinois, Industrial Physic’s world-leading gas, oxygen and moisture analysis brand, Systech 8101e devices are simple to operate. They increase your productivity while lowering costs. Setting a new benchmark in oxygen transmission rate testing, their OxySense® instruments incorporate the latest in coulometric sensor technology with high sensitivity and the widest test range.  

SKU: MDL-008101-E Category:

Description

8101e OxySense® Oxygen Transmission Rate Analyzer (OTR)

Systech Illinois introduces the 8101e, a state-of-the-art device for oxygen analysis, designed to maximize efficiency and significantly reduce operational costs. Unlike other devices that rely on expensive hydrogen-nitrogen mixtures, the 8101e utilizes pure oxygen and nitrogen, making it a much more economical choice for businesses.

One of the key advantages of the 8101e is its broad measurement range, spanning from 0.05 to 432,000 cc/(m²·d). This wide range allows it to outperform competitors, where multiple machines—often up to three—might be required to achieve the same level of functionality. The 8101e consolidates these capabilities into a single device, minimizing equipment costs and logistical complexities.

The 8101e is specifically engineered to meet the rigorous demands of industries including beverages, flexible packaging, barrier films, food, inks and coatings, paper and pulp, and plastics and polymers Whether you need to test oxygen transmission rates (OTR) in materials like packaging films, plastic containers, or coated paper, this device delivers precise and reliable results.

In addition to its wide range, the 8101e complies with international standards such as ASTM D3985 and offers the flexibility to switch between wet and dry testing in minutes. This ensures that businesses can quickly adapt their testing needs without sacrificing accuracy or productivity. With its combination of advanced sensor technology, cost-effectiveness, and versatility, the Systech Illinois 8101e is the perfect solution for OTR testing and moisture analysis across multiple material sectors.

Extensive oxygen transmission rate testing
With an 8101e device you can undertake flawless oxygen transmission rate testing on a wide range of materials, from barrier films, PET bottles and containers to bags and flexible pouches.

Sensors for all oxygen transmission rate testing
Choose the right sensor for your oxygen transmission rate testing to meet stringent international standards including ASTM D3985. Each device features an eMetric high sensitivity coulometric sensor offering a wide range from 0.05 to 432,000 cc/(m2 · d). You can even switch from wet to dry test inspection in just a few minutes.

Networked oxygen transmission rate testing
The OxySense 8101e features a full Windows® operating system for safe, secure operation and network connectivity.

Auto-Stop™ oxygen transmission rate testing
Our patented Auto-Stop™ feature allows you to program parameters into the software that will determine when equilibrium has been reached and automatically stop the test.

Validate your oxygen transmission rate testing
You can validate your 8101e system in just a few hours using third party certified gas.

Oxygen transmission rate testing support
When you invest in the 8101e you get remote, Internet based support. Give us the green light and we can access your instrument to diagnose and repair system errors without the cost and time involved with an on-site visit.

High standard oxygen transmission rate testing
You can rely on the 8101e OxySense® to give you highly accurate results to the most stringent of international standards, including:

  • ASTM D3985
    ASTM F1307
    ASTM F1927
    DIN 533803-3
    ISO CD 15105-2
    JIS 7126

More oxygen analyzer options
Across the IP portfolio we make a wide range of oxygen transmission rate testing devices. For example, we manufacture the low cost, reliable OxySense 8102 and OxySense 8107 machines. Then there’s our OxySense 8700 & 8701 permeability analyzers to consider – perhaps the ultimate oxygen transmission rate of polyethylene testing machines!

What’s suitable for 8101e oxygen transmission rate testing?
The 8101e oxygen transmission rate testing device is relied upon across the beverage, flexible packaging, food, inks and coatings, paper and pulp and plastics and polymers sectors.

It’s used for so many types of testing – from checking the oxygen transmission rate of packaging films to monitoring the oxygen transmission rate of polyethylene bags. Plus it’s ideal for testing PET bottles, containers and canisters.

Film testing
The 8101e will help you to understand the oxygen transmission rate of packaging films used in the food or the pharmaceutical industries. Use it to test plastic and composite films or even metalized films.

Packages testing
You can use the 8101e to undertake oxygen transmission rate testing of all kinds of plastic and composite. It’s great for oxygen transmission rate testing of plastic bottles, vacuum bags, engineered plastics, and building materials.

Unlock testing capabilities with the Profile Manager
Utilizing our Profile Manager, you can set-up ten different test conditions and the analyzer will automatically run through them all. Each test with unique temperatures and humidity conditions

Specifications

  • Applications: Permeation Testing
  • Materials: Film, Paper, Plastics and Polymers
  • Gas: oxygen
  • Application: permeation
  • Controlled RH testing ranges: films – carrier and test gas / packages – ambient or controlled by chamber
  • Test temperature range: 10°C to 40°C ± 0.1°C
  • cc/(m2 • day): 0.05 to 432,000
  • cc/(100in2 • day): 0.003 to 28,000
  • cc/(pkg • day): 0.00025 to 2000
  • Resolution cc/(m2 • day): 0.0001
  • Repeatability cc/(m2 • day): 0.015 or 1%

Features & Benefits

  • High sensitivity, wide range eMetric™ coulometric oxygen transmission rate sensor 
  • Widest test range 
  • Easy testing – just load the film and press a button to start 
  • Automatic relative humidity and temperature controls 
  • Oxygen transmission rate testing to multiple international standards
  • Expandable up to 32 cells
  • Fully automatic

Additional information

Gas

Oxygen

Application

Permeation

Controlled RH Testing Ranges

Films- Carrier and Test gas,
Packages – Ambient or controlled by chamber

Test temperature range

10°C to 40°C ± 0.1°C

  • High sensitivity, wide range eMetric™ coulometric oxygen transmission rate sensor
  • Widest test range
  • Easy testing – just load the film and press a button to start
  • Automatic relative humidity and temperature controls
  • Oxygen transmission rate testing to multiple international standards
  • Expandable up to 32 cells
  • Fully automatic